Editor's Note: Minutes received 7/28 CURRENT_MEETING_REPORT_ Reported by Tracy Cox/Bellcore Minutes of the DS1/DS3 MIB Working Group (TRUNKMIB) The decision of the Working Group, per Bill Versteeg's suggestion, was to completely obsolete RFC 1232 and RFC 1233, and remove all of the deprecated objects from this document. All tables have been given new names and new OIDs. The beginning delimiter for all objects is dsx* (* = 1 or 3). In addition, we added LESs to the near end tables, changed all Counters remaining (current table) to Gauges, and modified the dsx1LineCoding, dsx1LineStatus, dsx*SendCode Object descriptions, and added a Signaling Mode object (DS1 MIB only). We have an action item to resolve on whether to keep or remove the BPVs count. James Watt took an action item to supply appropriate text for the failure states description. A description of Line Errored Seconds (which T1M1 has available only from the far end, but we decided to include for the near end for symmetry's sake) was added. The DS1 and DS3 MIBs are available for anonymous FTP at fennel.acc.com. New Internet Drafts reflecting these changes will be sent to the trunk-mib mailing list and posted in the Internet-Drafts Directories; when consensus is achieved on the mailing list, they will be forwarded to the IESG for their review and approval as new RFCs obsoleting RFC1232 and RFC1233. Attendees Fred Baker fbaker@acc.com Alan Bryenton bryenton@bnr.ca Steve Buchko stevebu@newbridge.com Greg Celmainis gregc@newbridge.com Tracy Cox tacox@sabre.bellcore.com James Davin jrd@ptt.lcs.mit.edu Tom Easterday tom@cic.net John Labbe labbe@merit.edu Chris Sullivan mm@gandalf.ca Kaj Tesink kaj@cc.bellcore.com James Watt jamesw@newbridge.com 1